Vibrator Motor Selection: Speed, Centrifugal Force and Mounting
Key Takeaway: Choose vibrator motor speed by application: 2-pole for hopper discharge and compaction, 4-pole for general feeders and screens, 6 or 8-pole for coarse material. Centrifugal force rises with the square of speed. Set eccentric weights identically at both shaft ends and mount on a rigid surface.
How a Vibrator Motor Works
A vibrator motor is an induction motor with adjustable eccentric weights fitted to both ends of its shaft. As the shaft turns, the unbalanced weights generate a rotating centrifugal force that is transmitted through the motor feet into the machine structure. Selecting one means choosing the right speed and the right force for the material and the equipment.
Choose the Speed First
Speed sets the vibration frequency. High frequency gives small amplitude; low frequency gives large amplitude.
- 2-pole (3000 rpm): High frequency, small stroke. Hopper and silo discharge, compaction tables, fine powders, concrete formwork.
- 4-pole (1500 rpm): The general-purpose choice for vibrating feeders, conveyors and screening of fine to medium material.
- 6-pole (1000 rpm) and 8-pole (750 rpm): Low frequency, large stroke. Screening and feeding of coarse, heavy or sticky material in quarrying and mining.
Calculate the Centrifugal Force
Force (N) = Static moment (kg·m) × ω², where ω = 2π × rpm ÷ 60.
A motor with a static moment of 0.1 kg·m (10 kg·cm) at 1500 rpm produces 0.1 × 157² ≈ 2470 N, or about 250 kgf. The same weights at 3000 rpm would produce four times that force, because force rises with the square of speed. This is why weights are never transferred between motors of different speeds.
Relate Force to the Vibrating Mass
The total centrifugal force divided by the weight of everything that vibrates (machine body, motors and the material load on it) gives the acceleration in multiples of g. As a starting point, many screens and feeders are designed for roughly 3 to 5 g; the equipment builder's figure takes precedence.
The stroke can be estimated as:
Stroke, peak to peak (mm) = 2 × Total static moment (kg·mm) ÷ Vibrating mass (kg)
Two motors of 100 kg·mm each on a 400 kg vibrating mass give a stroke of 2 × 200 ÷ 400 = 1 mm.
One Motor or Two
- Single motor: Produces circular or elliptical motion. Used on hoppers, bins and circular-motion screens.
- Two motors, counter-rotating: The forces cancel in one direction and add in the other, producing linear motion. Used on linear screens and feeders to convey material in a defined direction.
Adjusting the Weights
Force is adjusted by changing the angle between the fixed and adjustable weights. The setting must be identical at both ends of the shaft, and identical on both motors of a twin-drive machine. Unequal settings twist the structure and overload the bearings.
Installation Rules
- Mount on a rigid, flat, clean surface. A flexible mounting plate will crack and will absorb the vibration instead of transmitting it.
- Use high-tensile bolts with locking nuts, tightened to the specified torque. Re-check the torque after the first few hours of operation.
- Use flexible cable with a slack loop at the motor so the cable does not fatigue.
- Give each motor its own overload protection. On twin-motor machines, interlock them so both stop if either one trips; running on one motor produces uncontrolled motion that can damage the structure.
- Never run the motor with the weight covers removed.
See the vibrator motor range, or share your machine weight, material and duty with the Sun Star Motors™ team for a recommendation.