Selection Guide 6 min read

Brake Motor Selection Guide for Cranes, Hoists and Conveyors

Key Takeaway: Industrial brake motors are fail-safe: springs apply the brake when power is lost. Hoisting duties commonly specify brake torque at 1.5 to 2 times rated motor torque. On a VFD, feed the brake coil from a separate supply. Check air gap and lining wear at regular intervals.

When a Standard Motor Is Not Enough

A standard induction motor coasts to a stop when power is removed. On a hoist, an inclined conveyor or an indexing machine, that is either unsafe or too slow. A brake motor adds an electromagnetic brake at the non-drive end so the load stops quickly and is held in position.

Fail-Safe Operation

Industrial brake motors use a spring-applied, power-released brake. Springs press the friction disc against the braking surface; energising the coil pulls the armature plate back and releases the brake. If supply fails, the springs apply the brake automatically. For any application that lifts or holds a load, this fail-safe principle is essential.

Sizing the Brake Torque

Start from the motor's rated torque: Torque (Nm) = 9550 × kW ÷ rpm. A 3.7 kW motor at 1440 rpm delivers about 24.5 Nm.

  • Horizontal conveyors and general stopping: Brake torque close to or moderately above the rated motor torque is usually sufficient.
  • Hoisting and holding duties: Brake torque is commonly specified at 1.5 to 2 times the rated motor torque, giving roughly 37 to 50 Nm for the motor above. The applicable crane or hoist standard for your installation takes precedence.

More torque is not always better. An oversized brake on a conveyor stops the load abruptly, shocks the gearbox and can spill or damage product.

AC or DC Brake Coil

  • DC brake (via rectifier): The most common arrangement. A rectifier in the terminal box feeds a DC coil. Operation is quiet, and switching on the DC side gives faster brake engagement.
  • AC brake: A three-phase coil fed directly from the supply. Response is very fast, which suits high-cycle applications.

Running on a VFD: The brake coil must be fed from a separate, fixed supply and not from the motor terminals. Inverter output voltage varies with speed, and the brake will not release reliably at low frequency.

Duty Cycle and Starts per Hour

Brake motors usually work in intermittent duty (S3 or S4). Each start heats the windings and each stop heats the friction lining. State the number of starts per hour and the load inertia when requesting a quotation; a motor suited to 60 starts an hour may not survive 300.

Options Worth Specifying

  • Manual release lever: Allows the load to be lowered or the machine to be positioned during a power failure or maintenance.
  • Brake supply voltage: Confirm it matches the control circuit available on site.
  • Enclosure protection: Dust and moisture on the friction surfaces reduce braking torque, so match the protection to the environment.

Maintenance Checks

  1. Air gap: As the lining wears, the gap between coil and armature plate grows until the coil can no longer release the brake. Measure and reset it at the interval given in the manual.
  2. Lining thickness: Replace the friction disc before it reaches the minimum thickness.
  3. Contamination: Oil or grease on the lining permanently reduces braking torque. Replace a contaminated disc; do not clean and reuse it.
  4. Rectifier: A failed rectifier leaves the brake applied while the motor drives against it, which overheats both.

See the brake motor and geared brake motor ranges, or send your duty details to the Sun Star Motors™ team for a selection.